BXRWM - PR-1141 PC-60 NAVY BLUE, PART B

Product Identification

Product ID:PR-1141 PC-60 NAVY BLUE, PART B
MSDS Date:09/12/1990
FSC:8010
NIIN:00N060347
Kit Part:Y
MSDS Number: BXRWM

Responsible Party
PRODUCTS RESEARCH & CHEMICAL CORP
5430 SAN FERNANDO RD
GLENDALE, CA 91209
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 818-240-2060

Preparer: R.D.C.

Cage: DO563

Contractor
PRODUCTS RESEARCH & CHEMICAL
1800 GLENDALE, CA 91209 US

Telephone: 818-240-2060

Cage: DO563

Ingredients

3.94. EVAP

CAS: 110-43-0

RTECS: MJ5075000

Fraction By Weight: 40%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM


POLYESTER POLYOL POLYMER WITH METHYLENE BIS(2-CYCLOHEXYL

CAS: 59330-00-6

Fraction By Weight: 30%

OSHA PEL N/K

ACGIH TLV: 0.005 PPM (MFR)


ISOCYANIC ACID, METHYLENEDI-4, 1-CYCLOHEXYLENE ESTER

CAS: 5124-30-1

RTECS: NQ9250000

OSHA PEL 0.01 PPM, C

ACGIH TLV: 0.005 PPM


POLYESTER POLYOL POLYMER W/ISOPHORONE DIISOCYANATE

CAS: 55636-48-1

Fraction By Weight: 30%

OSHA PEL N/K

ACGIH TLV: N/K


ISOCYANIC ACID, METHYLENE(3,5,5-TRIMETHYL-3,

CAS: 4098-71-9

RTECS: NQ9370000

OSHA PEL N/K

ACGIH TLV: 0.005 PPM


382 G/L.

RTECS: 9999999VO


MOISTURE CONTAMINATION IS SUSPECTED.

RTECS: 9999999ZZ


BY WALLS & VENTILATED BY LOC VENT, PROPERLY DESIGNED &

RTECS: 9999999ZZ


INDUSTRIAL VENT PUBLICATION OR OTHER APPROPRIATE

RTECS: 9999999ZZ


& FULL LENGTH FACESHIELD .

RTECS: 9999999ZZ


INCLUDING HEAD COVERING & OVERSHOES IS

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:VAPORS WILL CAUSE IRRITATION
W/WATERING. LIQUID CONTACT WILL CAUSE IRRITATION & POSSIBLE
PERMANENT DAMAGE. SKIN:LOCAL SWELLING, SORENESS, ITCHING. IN
SENSITIZED INDIVIDUALS, EXPOSURE TO LIQUID OR VAPORS WILL RESULT
IN AN ALLERGIC RASH. INHAL:IRRITATION OF NOSE, THROAT & EYES.
BRONCHIAL IRRITATION (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:W/COUGHING, TIGHTNESS IN CHEST &
POSSIBLE DIFFICULTY IN BREATHING. MAY PRODUCE ASTHMA-LIKE SYMPTOMS
IN SENSITIZED INDIVIDUALS. INGEST:IRRITATION OF DIGESTIVE TRACT &
STOMACH.
Medical Cond Aggravated by Exposure:INDIVIDUALS SUFFERING FROM ASTHMA
OR OTHER CHRONIC RESPIRATORY CONDITIONS MAY EXHIBIT A HEIGHTENED
SENSITIVITY TO ISOCYANATES & SHOULD AVOID INHALATION EXPOSURE.

First Aid

First Aid:EYES:FLUSH W/LUKE WARM WATER FOR AT LEAST 15 MINUTES. IF
SYMPTOMS PERSIST, CONSULT MD. SKIN:WASH W/SOAP & WATER. IF SYMPTOMS
PERSIST, CONSULT MD. INHAL:REMOVE TO FRESH AIR. IF SYMPTOMS ARE
PRESENT CON SULT MD. INGEST:CONSULT MD.

Fire Fighting

Flash Point Method:PMCC
Flash Point:102F,39C
Lower Limits:SEE ING 1.
Upper Limits:SEE ING 1.
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . USE WATER TO COOL HEAT EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:HIGH TEMPERATURES MAY CAUSE PRESSURE
BUILDUP IN CLOSED CONTAINERS.

Accidental Release

Spill Release Procedures:REMOVE ALL IGNIT SOURCES. WEAR NIOSH/MSHA
APPRVD AIR-SUPPLIED RESP FOR MAJOR UNVENTILATED SPILL. COVER
W/ABSORB MATL, ADD DECONTAM SOLN (5% CONC AMMONIA, 2% DETERGENT,
93% WATER) & ALLOW TO REACT FOR 10 MINS. COLLECT IN CNTNRS, ADD
ADDNL (SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DURING SPRAY APPLICATION, STRINGENT
PRECS MUST BE TAKEN TO ENSURE SFTY OF PERS INVOLVED W/APPLICATION,
OTHER PERS WORKING IN AREA & THE GEN PUBLIC.
Other Precautions:WHEN SPRAY APPLYING, USER MUST BE FULLY PROT FROM
CONT W/ANY OF MATL. OTHER PERS ENTERING AREA FOR ANY REASON MUST BE
SIMILARLY PROT. SPRAY APPLICATION SHOULD BE ISOLATED TO REDUCE
POTNTL FOR EXPOS. I N OPEN AREAS, AT LST 100 FEET (SUPDAT)

Exposure Controls

Respiratory Protection:WHEN APPLYING IN CONFINED AREAS, OR IN OTHER
CIRCUMSTANCES LIKELY TO PRODUCE AIRBORNE LEVELS OF SOLVENT OR
ISOCYANATE IN EXCESS OF PEL, USE A NIOSH/MSHA APPROVED AIR-SUPPLIED
RESPIRATOR.
Ventilation:GEN VENT TO MAINTAIN VAPS BELOW PEL. INSIDE SPRAY
APPLICATIONS SHOULD BE IN AREA SEPARATED FROM OTHER WORK AREAS (ING
8)
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(ING 10)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . FULL, PERMEATION RESIST, PROT SUIT (ING 11)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC:DECONTAM SOLN & KEEP LOOSELY COVERED FOR 48 HRS. OTHER
PREC:SHOULD SEPARATE THIS OPERATION FROM ANY PERS NOT PROT. UNPROT
PERS MUST BE PREVENTED FROM CONTACTING UNCURED RESIDUE ON EQUIP & A
REA SURFS UNTIL PROD HAS CURED. AVOID MOISTURE CONTAM WHICH WILL
CAUSE CO*2 PRESS. DO NOT RESEAL CNTNRS IF (ING 7)

Chemical Properties

Vapor Density:SEE ING 1
Spec Gravity:0.97
Evaporation Rate & Reference:SEE INGREDIENT 1.
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR VISCOUS LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
WATER, ALCOHOLS, STRONG BASES, AMINES, STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF CARBON.

Disposal

Waste Disposal Methods:EPA WASTE NO:D-001. DISPOSE OF SPILLAGE IN
COMPLIANCE W/FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.